Bonfiglioli AC Motor Sürücü Hata Kodları
Bonfiglioli AC Motor Sürücü Hata Kodları nı buradan Ctrl + F klavye kombinasyonu ile arayabilirsiniz.
Bonfiglioli sürücü tamiri için firmamız ile iletişim kurabilirsiniz.
Error messages | ||
Code | Meaning | |
F00 | 00 | No fault has occurred. |
Overload | ||
F01 | 00 | Frequency inverter overloaded, check load behaviour. Reduce ramps and speed. |
01 | Frequency inverter overloaded in low output frequency range. | |
02 | Frequency inverter overloaded (60 s), check load behaviour. | |
03 | Short-term overload (1 s), check motor and application parameters. | |
Heat Sink | ||
F02 | 00 | Heat sink temperature too high, check cooling and ventilator. |
01 | Heat sink temperature too cold, check allowed ambient temperature. | |
Inside | ||
F03 | 00 | Inside temperature too high, check cooling and ventilator. |
01 | Inside temperature too cold, check allowed ambient temperature. | |
03 | Capacitor temperature too high, check cooling and ventilator. | |
Motor connection | ||
F04 | 00 | Motor temperature too high or sensor defective, check connection at terminal X12.4. |
01 | Motor circuit breaker tripped, check drive. | |
02 | V-belt monitoring reports no load on the drive. | |
03 | Phase failure, check motor and wiring. | |
Output current | ||
F05 | 00 | Overloaded, check load situation and ramps. |
06 | Motor phase current too high, check motor and wiring. | |
07 | Message from phase monitoring, check motor and wiring. | |
08 | Message from phase monitoring, check motor and wiring. | |
09 | Message from phase monitoring, check motor and wiring. | |
11 | Motor still rotates. The motor is still excited and rotates and – drive start command applies and the flying start function is deactivated or – a device test is tried to start | |
Internal Error. | ||
F06 | xx | Internal Error. Please contact your Bonfiglioli office. |
DC–link voltage | ||
F07 | 00 | DC link voltage too high, check deceleration ramps and connected brake resistor. |
01 | DC link voltage too small, check mains voltage. | |
02 | Power failure, check mains voltage and circuit. | |
03 | Phase failure mains, check mains fuses and circuit. | |
04 | Reference DC-Link Limitation 680 too small, check mains voltage. | |
05 | Overvoltage brake chopper. Refer to chapter 13.3 “Troubleshooting” (Shut-down). | |
06 | Overvoltage motor chopper. Refer to chapter 13.3 “Troubleshooting” (Shut-down). | |
Electronics voltage | ||
F08 | 01 | Electronics voltage DC 24 V too low, check control terminal. |
04 | Electronics voltage too high, check wiring of control terminals. | |
05 | Fault in the the A/D converter. Remove all external connections (signal terminals etc.) and check if the fault remains |
Error messages | ||
Code | Meaning | |
06 | Voltage supply for optional communication module too low. Communication via bus system faulty. Disconnect bus system wiring and acknowledge the error message. Check connections and wiring of the bus system. Replace the communication module if the error occurs, even if the bus system is dis- connected. If the communication module is replaced and the error occurs, contact the service of BONFIGLIOLI. | |
Brake chopper | ||
F10 | 10 | Brake chopper overcurrent. Also refer to chapter 7.10.4 “Brake chopper and brake resist”. |
Output frequency | ||
F11 | 00 | Output frequency too high, check control signals and settings. |
01 | Maximum frequency achieved by control. Check deceleration ramps and connected brake resistor. | |
Enable | ||
F12 | 01 | The STO Diagnosis software recognized a fault in the STO switch-off paths. Check wiring, connect screens. Check the EMC environment. If the fault remains, exchange the device. |
02 | Fault of the STO diagnosis function. If the device remains after a new start up, ex- change the device. | |
04 | Internal Fault. Contact the BONFILGLIOLI customer service. | |
05 | Enable signals STOA and STOB were not actuated at the same time, but with a high time offset. Check the circuitry of the enable input signals. | |
06 | The voltage of the STO signals is too low. Check the dimensioning of the DC 24 V sup- ply, that supplies the STO inputs. | |
07 | The STO diagnosis software was not able to detect a clear defined STO level. Check the wiring and STO triggering device. Ensure, that clear signal levels can be received (DC 0 V / DC 24 V). If the fault persists, check if the fault persists with another drive. | |
08 | The STO diagnosis software has recognized that the STO signal levels of the device don’t correlate to each other at different measurement points. Check the wiring, put the screens on correctly. If the fault persists, exchange the device. | |
09 | The STO diagnosis software recognized that an STO signal is too high inside the de- vice. Check the wiring; apply a clear defined signal level (0V / 24 V). If the fault per- sists, exchange the device. | |
Motor connection | ||
F13 | 00 | Earth fault on output, check motor and wiring. |
10 | Minimum current monitoring, check motor and wiring. | |
Control connection | ||
F14 | 01 | Reference value on multifunctional input 1 faulty, check signal. |
02 | Reference value on multifunctional input 2 faulty, check signal. | |
07 | Overcurrent on multifunctional input 1, check signal. | |
08 | Overcurrent on multifunctional input 2, check signal. | |
09 | No actual value for technology controller. Missing actual value was reported according to setting for Operation mode actual value failure 440. | |
50 | Temperature measurement with KTY measuring resistor defective. Check signal and measuring resistor. | |
54 | External error; drive responded according to parameter setting for Operation mode ext. error 535. Error was triggered via the logic signal or digital input signal assigned to parameter External error 183. | |
Modbus and VABus | ||
F20 | 10 | Communication error according to parameter X21: VABus Watchdog-Timer 1502. |
11 | Communication error according to parameter CM: VABus Watchdog Timer 413. |
Error messages | |||
Code | Meaning | ||
CANopen | |||
F20 | 21 | CAN Bus OFF | |
22 | CAN Guarding | ||
23 | Error state | ||
24 | SYNC error (SYNC timing) | ||
25 | CAN error state | ||
26 | RxPDO1 length error | Number of received bytes differs from mapping. | |
27 | RxPDO2 length error | ||
28 | RxPDO3 length error | ||
2A | RxPDO1 Timeout | RxPDO was not received in expected time. Ensure, that the RxPDO can be received in the set up “Event time” (Subindex 5). | |
2B | RxPDO2 Timeout | ||
2C | RxPDO3 Timeout | ||
DeviceNet | |||
F20 | 5x | DeviceNet Fault. Please check DeviceNet manual. | |
Profibus | |||
F20 | 6x | Profibus Fault. Please check Profibus manual. | |
Internal Error. | |||
F20 | 7 | Internal Error. Please contact your Bonfiglioli office. | |
System bus | |||
F21 | nn | Fault message on system bus master when a fault at system bus slave occurs, nn = node-ID of slave (hex) | |
F22 | 00 | Communication fault, system bus, timeout sync-telegram | |
01 | Communication fault, system bus, timeout RxPDO1 | ||
02 | Communication fault, system bus, timeout RxPDO2 | ||
03 | Communication fault, system bus, timeout RxPDO3 | ||
10 | Communication fault, system bus, bus-off | ||
CANopen | |||
F23 | nn | Heartbeat error, nn = triggering node. | |
CM module recognition | |||
F24 | 00 | Unknown CM module. Check compatibility firmware and CM module. | |
Industrial Ethernet | |||
F27 | nn | Industrial Ethernet Fault. Please check manual of used Ethernet module. | |
EtherCAT | |||
F28 | nn | EtherCAT fault. | |
User Error | |||
F30 | 3n | User triggered Error of Internal PLC. Please check the application manual VPLC. | |
Optional components | |||
F0B | 13 | Assembly of communication module was done without disconnection of mains supply. Disconnect mains supply. | |
Internal monitoring | |||
F0C | 40 | After 6 warm starts in less than 3 minutes this fault is triggered, due to the expectation that a faulty programming of the PLC or the function table is at hand. Additionally the PLC / Function table is stopped (P. 1399 = 0 only in RAM). |